Landing flaps drive control unit

Individual boards

The power board has (besides the power stage) several current sensors and protective measures for the operation according to RTCA DO-160. The hardware measures are: reverse polarity, replaceable fuse and EMV measures (against electromagnetic signals) on the power board and ESD measures (against electrostatic discharge) on the micro-controller board. The software disconnects the unit in case of a short. The micro-controller also has a software model to monitor the motor temperature (without temperature sensor).

The size of the micro-controller board is 45 mm x 69 mm (1.8" x 2.7"). The power board (for 28 VDC, 15 A) has 85 mm x 94 mm (3.3" x 3.7"). The overall height is 40 mm (1.6").

Individual boards (Landing flaps drive control unit)
return to landing flaps control drive unit return to home